HP rx8640 使用串口连接MP口进行日志收集

今天发现HP主机面板上的cell1在闪黄灯,检查系统日志没有发现有告警信息。这时需要在MP上进行日志收集。在MP上进行日志收集步骤如下:

1.先用串口线连接MP口

2.打开超级终端,选com1,设置选“还原默认值”设置如下:

http://blufiles.storage.msn.com/y1pq9bGWB_foMcEQxyyUnWmRR3_bit2R6ypaQjXoKh2gs9r54TJhPYA3E7GTRzVhJUo?PARTNER=WRITER

3.连接后会提示MP Loing,输入帐号密码 Admin / Admin (注意在超级终端的 传送-》捕获文字 来保存你的信息到文件上)

3.MP登录后系统会提示“Console Login” ,这时直接按 CTRL+b就进到MP的模式了

4.进入MP模式后会看到菜单:

MP MAIN MENU:

CO: Consoles

VFP: Virtual Front Panel

CM: Command Menu

CL: Console Logs

SL: Show Event Logs

FW: Firmware Update

HE: Help

X: Exit Connection

5.选 SL 进入,会有子菜单:

[mp] MP> SL

EVENT LOG MENU:

FPL: Forward Progress Log

SEL: System Event Log

LIVE: Live Events

CLR: Clear FPL and SEL

Q: Quit

6.选 SEL ,进入下一级

[mp] MP:VW> SEL

Welcome to the SEL (System Event Log) Viewer

The following SEL navigation commands are available:

D: Dump log starting at current block for capture and analysis

F: Display first (oldest) block

L: Display last (newest) block

J: Jump to specified entry and display previous block

+: Display next (forward in time) block

-: Display previous (backward in time) block

: Repeat previous +/- command

: Repeat previous +/- command

?: Display help

^B: Exit viewer

The following event format options are available:

K: Keyword

R: Raw hex

T: Text

The following event filter options are available:

A: Alert level

C: Cell

U: Unfiltered

[mp] MP:VWR (,,+,-,?,F,L,J,D,K,R,T,A,C,U,^B) > [mp] D

选D.

1524 MP 0 2 44800ee800e00001 00ffffffff01ff68 CELL_OFF

1524 08/15/2007 04:14:00

1525 MP 0 2 44800ee800e00003 00ffffffff00ff68 CELL_OFF

1525 08/15/2007 04:14:00

1526 MP 0 2 448019db00e00005 000001ffffffff69 IOBP_OFF

......

然后再选 T

[mp] MP:VWR (,,+,-,?,F,L,J,D,K,R,T,A,C,U,^B) > [mp] T

Switching to text format.

然后按Enter或是Space会列出日志信息

[mp] MP:VWR (,,+,-,?,F,L,J,D,K,R,T,A,C,U,^B) > [mp]

Log Entry 1827: 10/10/2008 09:43:37

Alert level 2: Informational

Keyword: CACHE_CHECK_INFO

It indicates a cache error occurred and data field contains check info data.

Reporting Entity: System Firmware located in cabinet 0, slot 1, cpu 1

Problem Detail: 0x188019d500090521

0x4e801c9f11e00228 0x188019d500090521

0x4b001c9f11e00229 0x0100000048ef23c9

Log Entry 1826: 10/10/2008 09:43:37

Alert level 2: Informational

Keyword: MC_TIMESTAMP

MC: MC timestamp

Reporting Entity: System Firmware located in cabinet 0, slot 1, cpu 1

Implementation Dependent: 0x2008101000100305

0x568002b011e00226 0x2008101000100305

0x4b0002b011e00227 0x0100000048ef23c9

7.输入 ctrl+b ,然后再 q,回到主菜单:

MP MAIN MENU:

CO: Consoles

VFP: Virtual Front Panel

CM: Command Menu

CL: Console Logs

SL: Show Event Logs

FW: Firmware Update

HE: Help

X: Exit Connection

再入 CM ,输入 ps 查看状态信息

mp] MP:CM> ps

Display detailed status of the selected MP bus device.

The following MP bus devices were found:

+---+----+-----+-------+-------+-----------+

| | | | | | |

| | | Sys | | IO | Bulk Pwr |

|Cab| MP |Bkpln| Cells |Chassis| Supplies |

| # |M S| |0 1 2 3| 0 1 |0 1 2 3 4 5|

+---+----+-----+-------+-------+-----------+

| 0 |* *| * |* * | * * |* * * * |

+---+----+-----+-------+-------+-----------+

You may display detailed power and hardware status for the following items:

T - Cabinet

S - System Backplane

G - MP (Core I/O)

P - IO Chassis

C - Cell

Select Device: c

Enter cell number: 1

HW status for Cell 1 : FAILURE DETECTED

Power status : on, 1.8V VRM4 VOLTAGE FAULT

Faults above are latched. They are cleared just before the cell is powered on.

Boot is not blocked

PDH memory is shared

Processor Compatibility : OK

RIO cable status : connected

RIO cable connection physical location : PCI Domain 1

Core cell is cell 0

Attention Led is off

PDHC status Leds : ***-

CPU Module Slot 0 1 2 3

Populated P P P P

Local 48V Good * * * *

Power Enabled * * * *

Power Good * * * *

(* - True, P - Processor, T - Terminator)

| DIMM Presence |

| |

| Side: | A | B |

|Echelon: |01234567|01234567|

+---------+--------+--------+

| |**** **** |

1 1 1 1 1 1

VRM's 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5

Present : * * * * * * * * * * * * * * * *

Enabled : * * * * * * * * * * * * * * * *

Pwr Good : * * * * * * * * * * * * * * *

Front Side Bus Freq. : 267 MHz

CPU Core Freq. : 1600 MHz

CPU Part Number : 80549KE

System Boot Rom (SFW) firmware rev 007.048.000

PDH controller (PDHC) firmware rev B.023.003.033 built MON JAN 08 19:59:34 2007

[mp] MP:CM> ps

Display detailed status of the selected MP bus device.

The following MP bus devices were found:

+---+----+-----+-------+-------+-----------+

| | | | | | |

| | | Sys | | IO | Bulk Pwr |

|Cab| MP |Bkpln| Cells |Chassis| Supplies |

| # |M S| |0 1 2 3| 0 1 |0 1 2 3 4 5|

+---+----+-----+-------+-------+-----------+

| 0 |* *| * |* * | * * |* * * * |

+---+----+-----+-------+-------+-----------+

You may display detailed power and hardware status for the following items:

T - Cabinet

S - System Backplane

G - MP (Core I/O)

P - IO Chassis

C - Cell

Select Device: t

HW status for rx8640 cabinet : FAILURE DETECTED

Master/Slave failover is Enabled

Power switch is on

Right Door is closed

Top Door is closed

Left Door is closed

Total Power Available 4000 VA

Total Power Needed 2507 VA

Power Redundancy : redundant

Power Viability : viable

Power Status

---------------+-----+-------+-------+-----------+

| | | | |

| Sys | | IO | Bulk Pwr |

|Bkpln| Cells |Chassis| Supplies |

| |0 1 2 3| 0 1 |0 1 2 3 4 5|

---------------+-----+-------+-------+-----------+

Populated | * |* * | * * |* * * * |

Enabled | * |* * | * * |* * * * |

Power OK | * |* * | * * |* * * * |

Warning/Fault | | * | | |

Attention LED | | | | |

AC Line status:

Line A0 NOT PRESENT

Line B0 Present

Line A1 Present

Line B1 Present

-- Press to continue, or 'Q' to Quit --

Front Fan Speed : normal

Rear Fan speed : normal

I/O Bay Fan Speed : normal

Temperature state : normal

Main Fan Redundancy : redundant

I/O Fan Redundancy : redundant

Overtemp Shutdown Enabled

| BPS | PCI |

| Fans | Fans |

| 0 1 2 3 4 5 | 0 1 2 3 4 5 |

+-----------+-------------+-------------+

Populated | * * * * | * * * * * * |

Failing | | |

Failed | | |

| Standby/Main Fans | 1 1 1 1 1 1 1 1 1 1 2 |

| 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 |

+-----------+-------------------------------------------+

Populated | * * * * * * * * * * * * * * * * * * * * * |

Failing | |

|

Failed | |

| Cell Fans |

| CPU C |

| 0 1 2 3 C |

+-----------+------------+

Cell 0 | |

Populated | * * * * * |

Failing | |

Failed | |

Cell 1 | |

Populated | * * * * * |

Failing | |

Failed | |

8.输入 x ,x 退出

9.发日志发给HP工程师处理。